수크로스수산화제이철착염
Ferric Hydroxide Sucrose Complex
원료 코드 M261193 국내 제품 1개 (단일제 1 · 복합제 0)
🌐 미국 FDA 자료(영문 라벨·부작용 보고·리콜)가 있습니다. 한국어는 AI 번역 참고용이니 원문을 함께 확인하세요. 해외 정보 보기
이 성분만 든 제품 (단일제 1)
🌐 해외(미국) 정보 — 수크로스수산화제이철착염
미국 FDA·NLM 자료 · 2026-10-02 기준이 성분은 한국어 번역이 없습니다(검수 전 자동 번역 게시는 멈춰 두었습니다). 아래는 미국 FDA 원문입니다 — 원문 라벨(DailyMed).
Parenteral Iron Replacement [EPC]
미국에서 쓰이는 곳(적응증)
영어 원문 (미국 FDA 라벨)
Iron Sucrose Injection is indicated for the treatment of iron deficiency anemia (IDA) in patients with chronic kidney disease (CKD). Iron Sucrose Injection is an iron replacement product indicated for the treatment of iron deficiency anemia (IDA) in patients with chronic kidney disease (CKD).
쓰면 안 되는 경우
영어 원문 (미국 FDA 라벨)
Known hypersensitivity to Iron Sucrose Injection • Known hypersensitivity to Iron Sucrose Injection ( 4 )
주요 경고·주의
영어 원문 (미국 FDA 라벨)
• Hypersensitivity Reactions: Observe for signs and symptoms of hypersensitivity during and after Iron Sucrose Injection administration for at least 30 minutes and until clinically stable following completion of each administration. Only administer Iron Sucrose Injection when personnel and therapies are immediately available for the treatment of serious hypersensitivity reactions. ( 5.1 ) • Hypotension: May cause hypotension. Monitor for signs and symptoms of hypotension during and following each administration ( 5.2 ) • Iron Overload: Regularly monitor hematologic responses during therapy. Do not administer to patients with iron overload.( 5.3 ) 5.1 Hypersensitivity Reactions Serious hypersensitivity reactions, including anaphylactic-type reactions, some of which have been life-threatening and fatal, have been reported in patients receiving Iron Sucrose Injection. Patients may present with shock, clinically significant hypotension, loss of consciousness, and/or collapse. If hypersensitivity reactions or signs of intolerance occur during administration, stop Iron Sucrose Injection immediately. Monitor patients for signs and symptoms of hypersensitivity during and after Iron Sucrose Injection administration for at least 30 minutes and until clinically stable following completion of the infusion. Only administer Iron Sucrose Injection when personnel and therapies are immediately available for the treatment of serious hypersensitivity reactions. Most reactions associated with …
임신·특수 환자
영어 원문 (미국 FDA 라벨)
8.1 Pregnancy Risk Summary Published studies on intravenous iron sucrose treatment after the first trimester of pregnancy have not shown adverse maternal or fetal outcomes ( see Data ). Available reports of intravenous iron sucrose use in pregnant women during the first trimester are insufficient to assess the risk of major birth defects and miscarriage. There are risks to the mother and fetus associated with untreated IDA in pregnancy as well as risk to the fetus associated with maternal severe hypersensitivity reactions ( see Clinical Considerations ). Animal reproduction studies of iron sucrose administered to rats and rabbits during the period of organogenesis at elemental iron doses …
미국 제품명 Venofer, VENOFER (IRON SUCROSE)
미국 부작용 보고(FAERS)에 많이 나온 증상
미국 FDA에 접수된 이 성분 관련 보고 9,478건 가운데 많이 적힌 증상입니다. 보고 수는 약 때문이라는 증거가 아니며, 많이 쓰는 약일수록 많아집니다. 증상 이름의 한국어는 AI 번역(참고용)이라 영어 원어를 함께 적었습니다.
- 1 약물 과민반응drug hypersensitivity1,159
- 2 오심nausea1,021
- 3 호흡 곤란dyspnoea988
- 4 적응증 외 사용off label use640
- 5 소양증pruritus636
- 6 구토vomiting632
- 7 설사diarrhoea546
- 8 발진rash539
- 9 저혈압hypotension520
- 10 어지러움dizziness512
- 11 두통headache468
- 12 URTICARIA464
미국 리콜 기록
FDA 리콜(회수) 기록 3건 중 최근 3건 — 특정 회사·제조번호 제품의 회수로, 국내 제품과는 관계없을 수 있습니다.
- 2024.12.11 · 2등급 · American Regent, Inc. Presence of Particulate Matter: Potential for glass delamination from the vials.
- 2024.12.11 · 2등급 · American Regent, Inc. Presence of Particulate Matter: Potential for glass delamination from the vials.
- 2024.12.11 · 2등급 · American Regent, Inc. Presence of Particulate Matter: Potential for glass delamination from the vials.
출처: 미국 FDA openFDA(라벨·FAERS·리콜), 미국 국립의학도서관 RxNorm · DailyMed 원문 라벨. 한국어는 오픈드럭 서버 AI(gemma)가 자동 번역한 참고용(사람 검수 전)으로 오역이 있을 수 있으니 반드시 원문을 확인하세요.
